BGC-Argo synthetic profile file processing and format on Coriolis GDAC. Version 1.1
(Ifremer, Plouzane, France, 2019)
The current V3.1 Argo netCDF format that produces a pair of core- and b- profile files per cycle, with N_PROF > 1, allows storage of all profile information returned from BGC floats, in a manner that is as close to float ...
SCOR WG 142: Quality Control Procedures for Oxygen and Other Biogeochemical Sensors on Floats and Gliders. Recommendation for oxygen measurements from Argo floats, implementation of in-air-measurement routine to assure highest long-term accuracy.
(Ifremer, Plouzane, France, 2015)
As Argo has entered its second decade and chemical/biological sensor technology is improving constantly, the marine biogeochemistry community is starting to embrace the successful Argo float program. An augmentation of the ...
Processing Argo oxygen data at the DAC level. Version 2.2. Octobre 22nd 2016. [SUPERSEDED by http://dx.doi.org/10.25607/OBP-117]
(IFREMER for Argo Data Management, Villefranche-sur-Mer, France, 2016)
This document does NOT address the issue of oxygen data quality control (either real-time or delayed mode). As a preliminary step towards that goal, this document seeks to ensure that all countries deploying floats equipped ...
SCOR WG 142: Quality Control Procedures for Oxygen and Other Biogeochemical Sensors on Floats and Gliders. Recommendations on the conversion between oxygen quantities for Bio-Argo floats and other autonomous sensor platforms. Version 1.1
(Ifremer, Plouzane, France, 2018)
As Argo has entered its second decade and chemical/biological sensor technology is improving constantly, the marine biogeochemistry community is starting to embrace the successful Argo float program. An augmentation of the ...
Argo Quality Control Manual for dissolved oxygen concentration, Version 1.1. 28th September 2016. [SUPERSEDED by http://dx.doi.org/10.25607/OBP-118]
(IFREMER for Argo-BGC Group, Villefranche-sur-Mer, France, 2016)
This document is the Argo quality control manual for Dissolved oxygen concentration. It describes two levels of quality control:
• The first level is the real-time system that performs a set of agreed automatic checks.
• ...
Processing Argo oxygen data at the DAC level. Version 2.3.1, June 13th 2018.
(IFREMER for Argo Data Management, Villefranche-sur-Mer, France, 2018)
This document does NOT address the issue of oxygen data quality control (either real-time or delayed mode). As a preliminary step towards that goal, this document seeks to ensure that all countries deploying floats equipped ...
Argo quality control manual for dissolved oxygen concentration. Version 2.0, 23 October 2018.
(IFREMER for Argo BGC Group, Villefranche-sur-Mer, France, 2018)
This document is the Argo quality control manual for Dissolved oxygen concentration. It describes two levels of quality control:
• The first level is the real-time system that performs a set of agreed automatic ...