Show simple item record

dc.contributor.authorLangdon, C
dc.date.accessioned2017-11-24T20:21:13Z
dc.date.available2017-11-24T20:21:13Z
dc.date.issued2010
dc.identifier.citationLangdon, C. (2010) Determination of Dissolved Oxygen in Seaweater By Winkler Titration using Amperometric Technique. In, The GO-SHIP Repeat Hydrography Manual: A Collection of Expert Reports and Guidelines. Version 1, (eds Hood, E.M., C.L. Sabine, and B.M. Sloyan). 18pp.. (IOCCP Report Number 14; ICPO Publication Series Number 134). DOI: https://doi.org/10.25607/OBP-1350en_US
dc.identifier.urihttp://hdl.handle.net/11329/380
dc.identifier.urihttps://doi.org/10.25607/OBP-1350
dc.description.abstractThis paper describes procedures to be used for the determination of dissolved oxygen in discrete samples of seawater. These procedures are based on the modified Winkler titration method (Carpenter 1965). These modifications reduced the loss of I2 during the titration due to volatilization by optimizing the concentrations of the “pickling” reagents to encourage the formation of the more stable triiodide complex I3- and by adopting the whole-bottle titration method which eliminates the loss of I 2 during transfer of sample aliquots. This procedure is suitable for the measurement of the full range of oceanic oxygen c oncentrations (0-400 μmol kg -1 ) in uncontaminated seawater. The typical precision that can be achi eved using automated amperometric endpoint detection systems is ±0.15 μmol kg -1 . Carpenter (1965) established the accuracy of the method as <0.1% or ±0.3 μmol kg -1 . This procedure is unsuitable for seaw ater containing hydrogen sulfide (H 2 S). In oxygen- deficient regions (<5 μmol kg -1 ) a high concentration of nitrite (NO 2 - ) may cause a positive oxygen bias. Polluted waters may contain reducing sub stances that will react with the liberated I 2 resulting in a negative oxygen biasen_US
dc.language.isoenen_US
dc.relation.ispartofseriesICPO Publication Series;134
dc.relation.ispartofseriesIOCCP Report;14
dc.rightsCC0 1.0 Universal*
dc.rights.urihttp://creativecommons.org/publicdomain/zero/1.0/*
dc.subject.otherGO-SHIP
dc.titleDetermination of Dissolved Oxygen in Seawater by Winkler Titration Using The Amperometric Technique.en_US
dc.typeReport Sectionen_US
dc.description.statusPublisheden_US
dc.description.refereedRefereeden_US
dc.format.pagerange18pp.en_US
dc.subject.parameterDisciplineParameter Discipline::Chemical oceanographyen_US
dc.subject.dmProcessesData Management Practices::Data acquisitionen_US
dc.description.currentstatusCurrenten_US
dc.contributor.editorparentHood, E.M.
dc.contributor.editorparentSabine, C.L.
dc.contributor.editorparentSloyan, B.M.
dc.title.parentThe GO-SHIP Repeat Hydrography Manual: A Collection of Expert Reports and Guidelines. Version 1.en_US
obps.resourceurl.publisherhttp://www.go-ship.org/HydroMan.htmlen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

CC0 1.0 Universal
Except where otherwise noted, this item's license is described as CC0 1.0 Universal